Purpose
To determine the incidence of atypical ductal hyperplasia (ADH) in needle biopsy and the upgrade rate to carcinoma, and to evaluate difference in findings between the upgrade and non-upgrade groups.

Materials and Methods
Among 9660 needle biopsies performed over 48 months, we reviewed the radiologic and histopathologic findings of ADH and compared the differences in imaging findings (mammography and breast US) and biopsy methods between the upgrade and non-upgrade groups.

Results
The incidence of ADH was 1.7% (169/9660). Of 112 resected cases and 30 cases followed-up for over 2 years, 35 were upgraded to carcinoma (24.6%, 35/142). The upgrade rates were significantly different according to biopsy methods: US-guided core needle biopsy (US-CNB) (40.7%, 22/54) vs. stereotactic-vacuum-assisted biopsy (S-VAB) (16.0%, 12/75) vs. US-guided VAB (US-VAB) (7.7%, 1/13) (p = 0.002). Multivariable analysis showed that only US-CNB (odds ratio = 5.19, 95% confidence interval: 2.16?13.95, p < 0.001) was an independent predictor for pathologic upgrade. There was no upgrade when a sonographic mass was biopsied by US-VAB (n = 7)

Conclusion
The incidence of ADH was relatively low (1.7%) and the upgrade rate was 24.6%. Surgical excision should be considered because of the considerable upgrade rate, except in the case of US-VAB.